FAQ

GPU Server Dropping Cards or Throttling — How Do You Troubleshoot?

Published: 2026-11-18 | Views: 0

In one sentence: first work out whether the card is dropping off the bus or throttling. A dropped card (the device disappears from the operating system) usually relates to power delivery, the PCIe link, firmware/driver or cooling; throttling (still present but slower) usually relates to the thermal limit, the power limit or ECC errors. The two require completely different troubleshooting orders — mixing them just wastes time.

Step 1: identify the failure type in three minutes

  • nvidia-smi: check whether all 8 GPUs are present — a missing GPU means a dropped card;
  • nvidia-smi -q: check temperature, power, clocks, ECC error counts and Clocks Throttle Reasons;
  • nvidia-smi topo -m: check whether the NVLink/NVSwitch topology is complete — a missing link significantly hurts training throughput;
  • dmesg -T | grep -i xid: Xid errors are the key clue for telling hardware problems from software ones;
  • BMC/IPMI SEL log: look for power supply, fan and PCIe alerts.

Dropped card: check in this order

  1. Power: an 8-GPU chassis can draw 6–10 kW; check the number of PSUs, whether every power cable is connected, and whether a single feed has dropped out;
  2. Physical connections: GPU-to-riser gold fingers, riser-to-motherboard slots and NVLink bridges may be loose;
  3. PCIe link: lspci -vv shows link speed and width degradation; AER errors indicate a link problem;
  4. Firmware and driver: mismatched GPU firmware, motherboard BIOS and driver versions are a common trigger, especially with a new card in an older platform;
  5. Cooling: excessive inlet temperature triggers protective shutdown, which shows up as "it drops after running for a while";
  6. The card itself: once everything above is ruled out, swap slots and swap cards to isolate it.

Throttling: watch the three limits

TypeIndicatorWhat to do
Thermal limitGPU/HBM temperature near the maximum, fans already at full speedImprove rack inlet airflow, clean dust, adjust fan curves, check thermal contact
Power limitPower near the cap, Clocks Throttle Reasons shows SW Power CapAssess power headroom, adjust the power cap or schedule jobs in time slices
ECC / hardware degradationECC error counts rising, Xid 48/94/95 appearingTrack the growth rate and replace the card once it crosses the threshold

Xid error code quick reference

Xid 13 (graphics engine exception), 31 (memory page fault), 43 (GPU stopped processing), 48 (double-bit ECC error), 62 (microcontroller halt), 79 (GPU fell off the bus), 94 (contained ECC error), 95 (uncontained ECC error). Of these, 48/94/95 map directly to GPU memory, while 79 usually points to a link or power problem — when 79 appears, check power and the riser first.

When to replace the card and when it is a whole-system problem

If the same card still errors in another slot, the card is at fault; if a new card in the same slot still errors, the motherboard, riser or power is at fault; if several cards fail at once, suspect chassis power and cooling rather than "all the cards are dead". Following this order avoids unnecessary whole-system replacement.

Zhonglianda Technology sells, repairs and maintains both Oracle and NVIDIA GPU servers, with a parts warehouse in Longhua District, Shenzhen. Wear parts for H100/H200 — power supplies, risers, NICs and optical modules — are kept in stock, with 7×24×365 response and 2-hour on-site attendance for routine faults in Shenzhen. If a cluster keeps dropping cards and no root cause is found, run a chassis-level stress and power assessment rather than just swapping cards.

Related reading: H100/H200 procurement pitfalls checklist, How to outsource 7×24 operations for an AI training cluster?

Didn't find the answer you were looking for?