Oracle DE3-24C Storage Shelf 580W AC Power Supply 7354096
| Brand | Oracle |
| Model | 7354096 8217444 8207218 |
| Warranty | 3 months - 3 years |
Product Overview
The Oracle 580W AC Input Power Supply (part numbers 7354096 / 8217444 / 8207218) is the integrated fan-and-power cooling module for DE3-24C and DE3-24P disk shelves, built to the SBB standard as a customer-replaceable (CRU) hot-swap unit.
Key Specifications
| Model | 580 Watt AC Input Power Supply (integrated fan, SBB standard) |
|---|---|
| Part numbers | 7354096 / 8217444 / 8207218 |
| Rated power | 580W |
| Input | 100-240VAC, 50/60Hz wide-range adaptive |
| Input current | 8A max at 100V; 3A max at 240V |
| Efficiency | ~88% |
| Output | Multi-rail DC for backplane, drives, IOMs and cooling fans |
| Operation | Load-sharing, N+1 redundant; a single module failure does not affect the shelf |
| Structure | Power + fan integrated module (not separate PSU and fan) |
| Indicators | OK (green) / Fault (amber) LEDs; status, alarms, temperature and voltage visible in the BUI |
| Connector | Standard IEC C14 AC inlet; SBB backplane edge connector |
Compatibility
- Disk shelves: DE3-24C (4U, 24× 3.5" LFF SAS-3), DE3-24P (2U, 24× 2.5" SFF).
- ZFS storage heads: ZS3-4, ZS4-4.
- Related systems: Oracle FS1 and ODA back-end expansion shelves using DE3-24C.
- Compatible alternative part numbers: 7318547, 7345273, 7043627 (older 580W revision).
Installation Notes
- The DE3-24C chassis carries two PSU slots at the rear, one left and one right.
- An empty slot must be fitted with a filler panel to preserve the airflow path.
- Replacement is hot-swap CRU — no shutdown required.
Availability & Support
Tested pulled units in stock in Shenzhen, warranty 3 months to 3 years depending on batch. We pre-check the part number revision against your shelf before shipping and support on-site replacement in Shenzhen within 4 hours.
Frequently Asked Questions
Which part number should I order — 7354096, 8217444 or 8207218?
They are revisions of the same 580W DE3-24C power module; 7354096 is the current FRU. Older 7318547 / 7345273 / 7043627 units are also compatible. Send us your shelf serial or photo of the installed module and we match the exact revision.
Can I replace the PSU without shutting down the shelf?
Yes. The module is a hot-swap CRU: pull the failed unit and insert the replacement while the shelf keeps running, as long as the other module is healthy (N+1 redundancy).
Does one power module carry the full shelf on its own?
Yes for continued operation — the two modules share the load in N+1 mode, and a single healthy 580W module can keep the shelf and its 24 drives and IOMs alive, but the shelf runs without redundancy until the second module is restored.